IC693MDL731

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

IC693MDL731 Image

IC693MDL731

  • Availability: In Stock Ships Today!
  • Units in Stock: Immediate Availablity: 11 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: Negative Logic (8) 12/24 Volts dc Output, 2 Amp
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693MDL731 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z,

Product Manual Excerpt

12/24 Volt DC Negative Logic Output - 2 Amp, 8 Point IC693MDL731 The 12/24 volt DC Negative Logic 2 Amp Output module for the Series 90-30 Programmable Logic Controller provides 8 output points in one group with a common power output terminal. This output module is designed to have negative logic characteristics in that it sinks current from the loads to the user common or negative power bus. The output device is connected between the positive power bus and the module output. The output characteristics are compatible with a wide range of user-supplied load devices, such as: motor starters, solenoids, and indicators. Power to operate the field devices must be supplied by the user. LED indicators which provide the ON/OFF status of each point are located at the top of the module. This LED block has two horizontal rows with eight green LEDs in each row. This module uses only the top row labeled A1 through 8 (points 1 through 8). A red LED (labeled F )on the right and centered between the two rows of green LEDs functions as a blown fuse indicator; it turns ON when any fuse is blown. The module has two 5 amp fuses with each fuse protecting four outputs; the first fuse protects A1 - A4, the second fuse protects A5 - A8. The fuses are electrically connected to the same common. An insert goes between the inside and outside surface of the hinged door. The surface towards the inside of the module (when the hinged door is closed) has circuit wiring information, and circuit identification information can be recorded on the outside surface. The outside left edge of the insert is color-coded blue to indicate a low-voltage module. This module can be installed in any I/O slot of a 5 or 10-slot baseplate in a Series 90-30 PLC system. Table 7-8. Specifications for IC693MDL731 Rated Voltage 12/24 volts DC Output Voltage Range 12 to 24 volts DC (+20%, 15%) Outputs per Module 8 (one group of eight outputs) Isolation 1500 volts between field side and logic side Output Current 2 amps maximum per point 4 amps maximum per fuse at 50 C (122 F) 2 amps maximum per fuse at 60 C (140 F) Output Characteristics Output Voltage Drop 0.75 volts maximum Off-state Leakage 1 mA maximum On Response Time 2 ms maximum Off Response Time 2 ms maximum Power Consumption 55 mA (all outputs on) from 5 volt bus on backplane Maximum load current is dependent upon ambient temperature as shown in figure 2-27. Refer to Appendix B for product standards and general specifications. 7 7-16 Series 90-30 PLC I/O Module Specifications July 2000 GFK-0898F IC693MDL731 Output Module Field Wiring Information The following figure provides wiring information for connecting user supplied load devices and power source to the 12/24 volt DC negative logic 2 amp output module. TERMINALS FIELD WIRING 1 3 5 7 9 11 13 15 17 19 4 8 10 14 16 18 20 12 2 6 a43099 MODULE CIRCUITRY A1 A2 A3 1 f OTHER CIRCUITS A4 A5 A6 A7 μ Fuse for Outputs A1 A4 OTHER 5A CIRCUITS Fuse for Outputs A5 A8 OTHER CIRCUITS Figure 7-13. IC693MDL731 Output Module Field Wiring 10 C 20 C 30 C 50 C 60 C TOTAL MODULE LOAD CURRENT AMBIENT TEMPERATURE ( C) a43836 2A PER POINT 40 C 4 AMPS 1A PER POINT 8 6 4 2 (AMPS) Figure 7-14. Load Current vs. Temperature for IC693MDL731 Discrete Output Modules 7 GFK-0898F Chapter 7 Discrete Output Modules 7-17 Installing and Removing IC693MDL731 Terminal Boards with Holding Screws Discrete output modules IC693MDL730F (and later) and IC693MDL731F (and later) have a special terminal board that is equipped with holding screws, as shown in the figure below. These screws prevent the terminal board-to-module connections from deteriorating in applications where the PLC is subjected to severe vibration .