IC693MDL654

GE-IP | 9030 | GE Fanuc 90-30 GE-IP PLC

IC693MDL654 Image

IC693MDL654

  • Availability: In Stock Ships Today!
  • Units in Stock: Immediate Availablity: 7 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE-IP
  • Description: Neg/Pos Logic 5/12 Volts dc (TTL) Input
  • Weight: 1 lbs :: ≈ 1 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC693MDL654 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z,

Product Manual Excerpt

5/12 VDC (TTL) Positive/Negative Logic, 32 Point Input IC693MDL654 The 5/12 volt DC (TTL) Positive/Negative Logic Input module for the Series 90-30 Programmable Logic Controller provides 32 discrete TTL voltage threshold input points. The inputs are arranged in four isolated groups of eight (A1 - A8, B1 - B8, C1 - C8, and D1 - D8); each group has its own common. The inputs are positive or negative logic inputs and will operate at levels up to 15V. To be compatible with TTL outputs, the negative logic configuration should be used as shown in the following diagram. USER CIRCUIT 5V TTL IC OUTPUT COMx INPUTx MODULE INPUT a45035 A single, regulated +5V supply (current limited to approximately 150 mA) is available through the I/O connectors on the front of the module. This supply is generated on the module and is isolated from the backplane. Its power input comes from the +5V logic supply on the PLC backplane. By installing jumpers on the appropriate pins on the I/O connector, you can choose to power the inputs from this internal supply instead of powering them with an external user provided supply. If this internal supply is used to power the inputs, additional loading will be placed on the PLC s +5V power supply. Backplane isolation between the field side and logic side is provided by opto-couplers on the module. There are no special fault or alarm diagnostics reported. LED indicators (labeled A1 - A8, B1 - B8, C1 - C8, D1 - D8) at the top of the module provide the ON/OFF status of each input point. This module is configured as a 32-point input type and uses 32 bits of discrete %I input data. Current into an input point results in a logic 1 in the input status table. This module can be installed in any I/O slot of a 5 or 10-slot baseplate in a Series 90-30 PLC system. Connections to the input circuits are made from the user s input devices to two male (pin-type) 24-pin connectors (Fujitsu FCN-365P024-AU) mounted on the front of the module. The connector mounted on the right of the module (front view) interfaces with groups A and B. The connector on the left side of the module interfaces with groups C and D. Wiring from the module s connectors to field devices is made through a cable having a mating female connector on one end and stripped and tinned wires on the other end. You can purchase a pair of pre-wired cables, catalog numbers IC693CBL327 and IC693CBL328 or, if required for your application, build your own cable. Refer to Building Cables for 24-Pin Connectors in the IC693CBL327/328 data sheet in Appendix C of this manual for more information. 6 6-22 Series 90-30 PLC I/O Module Specifications July 2000 GFK-0898F Table 6-11. Specifications for IC693MDL654 Rated Voltage 5 to 12 volts DC, Positive or Negative Logic Input Voltage Range 0 to 15 volts DC Inputs per Module 32 (four groups of eight inputs each) 98.4 feet (30 meters) , maximum cable length Isolation 1500 volts between field side and logic side 250 volts between groups Input Current 3.0 mA (typical ON current @ 5 VDC) 8.5 mA (typical ON current @ 12 VDC) Input Characteristics On-state Voltage 4.2 to 15 volts DC Off-state Voltage 0 to 2.6 volts DC On-state Current 2.5 mA (minimum) Off-state Current 1.2 mA (maximum) On response Time 1 ms maximum Off response Time 1 ms maximum Internal Power Consumption 195 mA (maximum) from +5V bus on backplane; (29 mA + 0.5 mA/point ON + 4.7 mA/LED ON) 440 mA (maximum) from +5V bus on backplane (if module isolated +5V supply used to power inputs and all 32 inputs ON) 96 mA (typical) from user input supply @ 5 VDC and all 32 inputs ON) 272 mA (typical) from user input supply @ 12 VDC and all 32 inputs ON) Isolated +5V Supply +5 volts DC 5% Current limit 150 mA (typical) Maximum number of inputs ON is dependent on ambient temperature as shown in the figure below. Refer to data sheet GFK-0867C, or later revision for product standards and general specifications. 10 C 20 C 30 C 50 C 60 C NUMBER OF INPUTS/GROUP ON AMBIENT TEMPERATURE ( C) 40 C 5/12V SUPPLY 4 INPUTS PER GROUP ON 15V SUPPLY 8 6 4 2 a45136 Figure 6-17. Input Points vs. Temperature for IC693MDL654 Discrete Input Modules 6 GFK-0898F Chapter 6 Discrete Input Modules 6-23 IC693MDL654 Input Module Field Wiring Information The following figures provide wiring information for connecting user supplied input devices and power source to the 5/12 volt DC (TTL) pos/neg logic input module. 0.5W 1.3K 820 INPUT COMMON 5V 5V 0V 56K 10K a45036 0V ICS MODE 1 MODE 0 0V LED 680 0.01 0.22 μf 5V a45037 INTERNAL*LY GENERATED +5V SUPPLY MAY BE USED IN PLACE OF AN EXTERNAL USER SUPPLY A5 A3 B2 B4 B6 B8 A7 A1 B12 B11 B10 B9 B8 B7 B6 B1 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 B5 B4 B3 B2 NC ACOM +5V (OUT)* * I/O CONN (AB) D5 D3 C2 C4 C6 C8 D7 D1 A1 A2 A3 A4 A5 A6 A7 A12 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 A8 A9 A10 A11 NC DCOM (OUT) C1 NC 0V NC I/O CONN (CD) = FUJITSU CONNECTOR PINS A1 A12, B1 B12. MODULE POINT NUMBERS ARE SHOWN IN BOLD TEXT. Figure 6-18. Field Wiring 5/12 Volt DC (TTL) Pos/Neg Logic 32-Point Input Module - IC69MDL654 6 6-24 Series 90-30 PLC I/O Module Specifications July 2000 GFK-0898F Field Wiring Work Sheet for IC693MDL654 The following table is provided for the convenience of our customers as an aid to wiring 32-point I/O modules that have 24-pin connectors using cable IC693CBL315. It includes all of the required wiring information in one table. This table has the following information: module point number: A1 - A8, B1 - B8, C1 - C8, D1 - D8, voltage and common points connector pin number: A1 through A12, and B1 through B12 cable pair number: pair 1 through pair 12 wire color code: base color or base color with tracer color Columns are also provided for circuit references and customer wire numbers. Please copy and use the work sheets on this and the following page as needed when wiring the 5/12 VDC (TTL) Positive/Negative Logic, 32 Point Input module. Wiring for Module Groups A and B (connector on right front of module) Reference Module Point Number Connector Pin Number Cable Pair Number Wire Color Code Wire Number A1 A1 1 Brown A2 B1 7 Violet A3 A2 1 Brown/Black A4 B2 7 Violet/Black A5 A3 2 Red A6 B3 8 White A7 A4 2 Red/Black A8 B4 8 White/Black A Common A5 3 Orange N/C B5 9 Gray N/C A6 3 Orange/Black +5V OUT B6 9 Gray/Black 0 VOLTS A7 4 Yellow N/C B7 10 Pink N/C A8 4 Yellow/Black B Common B8 10 Pink/Black B8 A9 5 Dark Green B7 B9 11 Light Blue B6 A10 5 Dark Green/Black B5 B10 11 Light Blue/Black B4 A11 6 Dark Blue B3 B11 12 Light Green B2 A12 6 Dark Blue/Black B1 B12 12 Light Green/Black Discrete Input Modules 6 GFK-0898F Chapter 6 Discrete Input Modules 6-25 Wiring for Module Groups C and D (connector on left front of module) Reference Module Point Number Connector Pin Number Cable Pair Number Wire Color Code Wire Number C1 A1 1 Brown C2 B1 7 Violet C3 A2 1 Brown/Black C4 B2 7 Violet/Black C5 A3 2 Red C6 B3 8 White C7 A4 2 Red/Black C8 B4 8 White/Black C Common A5 3 Orange N/C B5 9 Gray N/C A6 3 Orange/Black +5V OUT B6 9 Gray/Black 0 VOLTS A7 4 Yellow N/C B7 10 Pink N/C A8 4 Yellow/Black D Common B8 10 Pink/Black D8 A9 5 Dark Green D7 B9 11 Light Blue D6 A10 5 Dark Green/Black D5 B10 11 Light Blue/Black D4 A11 6 Dark Blue D3 B11 12 Light Green D2 A12 6 Dark Blue/Black D1 B12 12 Light Green/Blac